Codian MCU 4200 Series Remote Management API
Response Type Comments
conferenceName string
conferenceType string one of:
scheduled
ad_hoc
conferenceActive boolean indicates whether conference is currently active
description string extra user-specified information about the conference
pin string the security PIN
numericId string
registerWithGatekeeper boolean
multicastStreamingEnabled boolean
unicastStreamingEnabled boolean
h239Enabled boolean
maximumAudioPorts int
maximumVideoPorts int
reservedAudioPorts int
reservedVideoPorts int
These fields set the limit on number of audio (audio
only) and video (video + audio) ports for the
conference. The “reserved” values are for port
reservation mode, whereas the “maximum” figures
apply to non-reserved mode (and will be absent if no
limits have been configured).
The following timing fields will be present for scheduled conferences only
startTime dateTime.iso8601 The time at which the conference started at or will start
at.
durationSeconds int How long each repeating instance of the conference
should last for – if absent, the conference is permanent.
repetition(optional) string one of:
none
daily
weekly
everyTwoWeeks
monthly
weekDay(optional) string Must be present if repetition is monthly.
One of:
monday
tuesday
wednesday
thursday
friday
saturday
Sunday
whichWeek (optional) string Must be present if repetition is monthly
one of:
first = first X of the month (where X is the day specified
by weekday)
second
third
fourth
last = last X of the month
weekDays (optional) string A comma separated string of weekdays from the
Copyright © Codian Ltd. 2004 - 2006 Codian Confidential Page 17